45:5A-54 Requirements of perimeter fence intrusion protection system.
   2.   A perimeter fence intrusion protection system shall:

   a.   interface with a monitored alarm device in a manner that enables the burglar alarm system to transmit a signal intended to summon the business or law enforcement, or both, in response to an intrusion or burglary;
 
   b.   be located on property that is not designated by a municipality exclusively for residential use;
 
   c.   have an energizer that is driven by a commercial storage battery that is not more than 12 volts of direct current;
 
   d.   have an energizer that meets the standards set forth by the International Electrotechnical Commission Standard 60335-2-76, in its current edition, and as amended and supplemented;
 
   e.   be surrounded by a nonelectric perimeter fence or wall that is not less than five feet in height;
 
   f.   not exceed ten feet in height or two feet higher than the nonelectric perimeter fence or wall described in subsection e. of this section, whichever is higher;
 
   g.   be marked with conspicuous warning signs that are located on the perimeter fence intrusion protection system at not more than 40 foot intervals and that read: "WARNING-ELECTRIC FENCE";
 
   h.   comply with the requirements set forth in the rules and regulations adopted by the board; and
 
   i.   be installed by a person trained by the manufacturer or certified in the installation, maintenance, repair, safety and operation of the perimeter fence intrusion protection system.
 
   L.2021, c.2, s.2.